Problems and matters needing attention in the use of Camera Module probe
Camera Module manufacturers are currently playing an increasingly important role in the development of industrial enterprises. Any precise device needs to be inspected regularly so as not to affect people's daily life and production; however, when using endoscopes, due to Improper operation methods will inevitably lead to various failures. If the detection effect is not deviated due to improper operation, it is greater than the gain.
The endoscope can be divided into three parts: the main body, the catheter and the probe. In addition to controlling the keys and screen of the host, the front-end probe can also be regarded as a very important core component, which can determine the quality of the image and the illumination of the optical fiber. It directly determines the success or failure of inspection quality.
Usually on the top of the camera, the lighting fiber bundle is wrapped inside, and the guiding tungsten wire determines the transmission signal of the video information. If non-standard enterprises can operate or develop by being hit by heavy objects, the probes of electronic endoscopes in my country will be damaged to a certain extent. So, what are the problems that usually occur when the probe of the Camera Module is used? What should I pay attention to when using it? Next, Xiaobian will share it with you.
1. If the probe is pressed or deformed, the image information collected by the probe cannot be converted normally, and the image on the display screen will appear abnormal: Huaping or Color distortion, etc.;
2. If the internal illumination fiber of the probe is seriously damaged, it will affect the transmission of the optical fiber network, resulting in excessive brightness or weakened brightness, affecting the clarity of the entire picture;
3. If the video signal in the probe is damaged, the video signal cannot be transmitted normally, and the county grain district cannot receive the image processing signal, or a black screen occurs;
4. If the probe The front lens of the camera is not seriously damaged, the light pipe is cracked, the language output light of the lens will diverge, and the measured object cannot capture the picture in time when shooting, and the operation cannot be realized;
The Camera Module probe will encounter various injuries during frequent operation. These problems will definitely affect the use of the machine. What should be paid attention to in daily use?
1. Before using the lens barrel for endoscopic surgery, make sure that one lens is in a straight line. When the cannula is crimped, the enterprise is prohibited from turning.
2. During the daily placement process, the probe should not be squeezed, bent or dropped to avoid system failure
3. The probe can not be used because it has been immersed in water for a long time. After the work is completed, it must be wiped and placed through the probe as soon as possible;
4. When the camera probe is bent again, it should not be taken out of the pipe directly. Before taking it out, it should be controlled by the joystick, and must not be pulled by hand;
5. After using in harsh social environment, you must pay attention to the development and cleaning of the lens language, you can wipe it clean with a dust-free cloth, so as not to affect the next use;
The Camera Module probe will inevitably cause various damages during use. Whether it is a guide, lighting or display problem, you must contact the manufacturer as soon as possible;
Camera Module https://www.hengal-tech.com/p-Camera-Module/4.html
- Art
- Causes
- Crafts
- Dance
- Drinks
- Film
- Fitness
- Food
- الألعاب
- Gardening
- Health
- الرئيسية
- Literature
- Music
- Networking
- أخرى
- Party
- Religion
- Shopping
- Sports
- Theater
- Wellness